BMRMP - NO. 5940 WHITE TRAFFIC PAINT

  • MSDS: BMRMP
  • Manufacturer: PERVO PAINT CO
  • Product Name: NO. 5940 WHITE TRAFFIC PAINT
  • National Stock Number: 8010-00N026198
Product Identification

Product ID:NO. 5940 WHITE TRAFFIC PAINT
MSDS Date:01/24/1990
FSC:8010
NIIN:00N026198
MSDS Number: BMRMP

Responsible Party
PERVO PAINT CO
6624 STANFORD AVE
LOS ANGELES, CA 90001
US

Emergency Phone: 213-758-1147

Info Phone: 213-758-1147

Cage: 86483

Contractor
PERVO PAINT CO
LOS ANGELES, CA 90001 US

Telephone: 213-758-1147

Cage: 86483

Ingredients

NAPHTHA, LIGHT ALIPHATIC (PETROLEUM); (ALIPHATIC

CAS: 64742-89-8

OSHA PEL 400 PPM (MFR)

ACGIH TLV: 400 PPM (MFR)


METHANOL; (METHYL ALCOHOL)

CAS: 67-56-1

RTECS: PC1400000

OSHA PEL S,200PPM/250STEL

ACGIH TLV: S,200PPM/250STEL; 93

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


PROPANE, 1,2-EPOXY-; (PROPYLENE OXIDE)

CAS: 75-56-9

RTECS: TZ2975000

OSHA PEL 100 PPM

ACGIH TLV: 20 PPM; 9293

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


1,1,1-TRICHLOROETHANE; (CHLOROTHENE SM)

CAS: 71-55-6

RTECS: KJ2975000

OSHA PEL 350 PPM;450 PPM,STEL

ACGIH TLV: 350 PPM;450 PPM,STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


2-BUTANONE; (METHYL ETHYL KETONE)

CAS: 78-93-3

RTECS: EL6475000

OSHA PEL 200 PPM;300 PPM STEL

ACGIH TLV: 200 PPM;300 PPM STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


P-DIOXANE; (DIETHYLENE DIOXIDE)

CAS: 123-91-1

RTECS: JG8225000

Fraction By Weight: TRACE

OSHA PEL S, 100 PPM

ACGIH TLV: S, 25 PPM; 9293

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


CARBON TETRACHLORIDE

CAS: 56-23-5

RTECS: FG4900000

Fraction By Weight: TRACE

OSHA PEL 10 PPM

ACGIH TLV: S,5PPM/10 STEL,A3 93

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS

Hazards

LD50 LC50 Mixture:LD50: (ORAL, RAT) 7G/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATLS HAVE PRODUCED
SENSITIZATION OF THE MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS &
COULD HAVE A SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G.,
EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FO R LIFE-SUSTAINING
USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO CHLOROCARBONS .
(SUPP DATA)
Explanation of Carcinogenicity:PROPYLENE OXIDE:GRP 2A (IARC), GRP 2
(NTP); DIOXANE (1,4): GRP 2B (IARC), GRP 2 (NTP); CARBON
TETRACHLORIDE: (SUPP DATA)
Effects of Overexposure:IRRITATION, GIDDINESS, HEADACHE, AND NAUSEA. IN
EXTREME CASES, ASPIRATION PNEUMONITIS, EVIDENCED BY COUGHING,
LABORED BREATHING AND CYANOSIS.
Medical Cond Aggravated by Exposure:PREEXISTING EYE, SKIN AND
RESPIRATORY DISORDERS MAY BE AGGRAVATED BY EXPOSURE TO THIS
PRODUCT.

First Aid

First Aid:EYES/SKIN: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. INHAL:
REMOVE TO FRESH AIR AND PROVIDE OXYGEN. IF VICTIM IS NOT BREATHING
PROVIDE ARTIFICIAL RESPIRATION. INGEST: CALL MD IMMEDIATELY .

Fire Fighting

Flash Point Method:TCC
Flash Point:55.0F,12.8C
Lower Limits:1.3%
Upper Limits:6.7%
Extinguishing Media:CO*2, FOAM, OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT . BLANKET VAPORS WITH EXTINGUISHING
MEDIA.
Unusual Fire/Explosion Hazard:THERMAL DECOMP PROD MAY INCLUDE HCL &
PHOSGENE . FLAMM VAP CAN FORM EXPLO MIXTURE W/AIR. CORR VAP
PRODUCED BY THERMAL DECOMP OF CHLORINATE HYDROCARBONS.

Accidental Release

Spill Release Procedures:WARNING: FLAMM MATERIAL. HANDLING EQUIPMENT TO
BE GROUNDED TO PREVENT SPARKING. USE NIOSH/MSHA APPROVED
RESPIRATORS. USE ABSORBANTS SUCH AS CLAY TO SOAK UP RESIDUES. FLUSH
WITH WATER. DISPOSE RESIDUES /FLUSH WATERS I/A/W REGULATIONS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE COOL, AWAY FROM SPKS/OPEN
FLAMES.KEEP FIRE EXTING IN & CLOSE TO STORAGE AREA.EMPTY CNTNRS
HAVE ALSO POTENTIAL FOR HAZ FROM FROM REMAINING FUMES.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF HCL AND/OR PHOSGENE .

Exposure Controls

Respiratory Protection:EITHER ATMOSPHERE SUPPLYING OR AIR SUPPLYING
NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:RECOMMENDED. LOCAL EXHAUST: RECOMMENDED. MECH
(GENERAL)/SPECIAL/OTHER: AS NEEDED.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WEAR SHOES AND CLOTHING OF NON ABSORBANT
NATURE TO PREVENT OVER EXPOSURE.
Work Hygienic Practices:USE EXPLOSION PROOF VENTILATION EQUIPMENT. DO
NOT USE AIR DRIED CONTAMINATED CLOTHING WITHOUT LAUNDERING.
Supplemental Safety and Health
MATLS TO AVOID:OF THIS PROD W/EQUIP CNTNG ANY ALUMINUM COMPONENTS. HLTH
HAZ:INHAL:IRRIT TO NOSE/THROAT/RESP TRACT.MAY PRDCE CNS
DEPRESS.EYE:IRRIT.SKIN:IRRIT. PRLNGD CONT CAUSES DEFAT OF SKIN
CAUSING D ERM.INGEST:MAY RESULT IN VOMIT. ASPIR/VOMITUS INTO LUNGS
CAUSES ASPIR PNEUMIT.EXPLAN OF CARCIN:GRP 2B(IARC),GRP 2 (NTP).

Chemical Properties

HCC:F5
Boiling Pt:B.P. Text:165F,74C
Vapor Pres:100
Vapor Density:4.5
Spec Gravity:1.76
Solubility in Water:NEGLIGIBLE
Appearance and Odor:WHITE LIQUID WITH AROMATIC ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING, REDUCING AGENTS IN CONJUNCTION W/HEAT. AVOID CONT
W/ANY FREE RADICAL GENERATORS. AVOID USE (SUPP DATA)
Stability Condition to Avoid:KEEP AWAY FROM HEAT, SPARKS, HEATED
SURFACES, STORE IN CLOSED CONTAINERS.
Hazardous Decomposition Products:HCL, PHOSGENE . OXIDES OF CARBON,
HYDROGEN CHLORIDE.
Conditions to Avoid Polymerization:HEAT, POLYMERIZATION INITIATORS.

Disposal

Waste Disposal Methods:TO BE DISPOSED OF IN CLOSED METAL CONTAINERS
I/A/W FEDERAL, STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.